Professional Manufacturer of Rapid Test Devices

About Us
Factory Tour
Quality Control
Contact Us
Home ProductsDrug Rapid Test Kit

Vitro Diagnostic 100 Kit 5Min AMP Drug Abuse Screening Strip

China Newscen Biopharm Co., Limited certification
China Newscen Biopharm Co., Limited certification
your products are very excellent, we find your products are proved so accurate through our much application , thank you so much for your nice kits and service

—— Ronnie

We appreciate your colleagues outstanding service, your work is so meticulous, your IVD products performance is so good too, you deserved trust

—— Vans

I'm Online Chat Now

Vitro Diagnostic 100 Kit 5Min AMP Drug Abuse Screening Strip

Vitro Diagnostic 100 Kit 5Min AMP Drug Abuse Screening Strip
Vitro Diagnostic 100 Kit 5Min AMP Drug Abuse Screening Strip Vitro Diagnostic 100 Kit 5Min AMP Drug Abuse Screening Strip Vitro Diagnostic 100 Kit 5Min AMP Drug Abuse Screening Strip Vitro Diagnostic 100 Kit 5Min AMP Drug Abuse Screening Strip

Large Image :  Vitro Diagnostic 100 Kit 5Min AMP Drug Abuse Screening Strip

Product Details:
Place of Origin: China
Brand Name: Newscen
Certification: ISO9001, CE, TUV, FDA
Model Number: AMP
Payment & Shipping Terms:
Minimum Order Quantity: 10 Boxes or 400 Kits (40 Kits/Box)
Price: Negotiable as per Order Quantity
Packaging Details: 40 Kits/Box, 50 Boxes/Carton, 317g/Box, 18kgs/Carton, Box Size: 250x125x65mm, Carton Size: 650x510x330mm
Delivery Time: 8 days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 100,000 Kits Per Day
Detailed Product Description
Category: Drug Abuse Detection Methodology: Colloidal Gold
Format: Cassette / Strip Box Color: Yellow
CE Certificate: YES Manufacturer/Trader: Manufacturer
High Light:

100 kit Drug Abuse Screening Strip

,

5Min AMP Drug Abuse test Strip

,

Vitro Diagnostic Drug Rapid Test Kit

AMP Gold Rapid Screen Test Strip

 

For the qualitative detection of Amp in urine
 
Main Features


☀ Reliable: high accurate, early detection of the presence of AMP


☀ Simple: No Instrument Required


☀ Convenient: Room Temperature Storage, Built-In Control line


☀ Fast: Results in 5-30 minutes, strong positive results may be observed promptly within 3 minutes


☀ Certified by Authoritative Certification System and Standards


☀ Winner of "the National Rapid Diagnostic Kit for Clinical Performance Assessment"

 

Intended Use

 

The AMP Gold Rapid Screen Test Strip is a qualitative competitive binding immunoassay for determination of Amphetamine in urine.

 

Summary and Explanation of The Test

 

The AMP Gold Rapid Screen Test Strip employs combination of monoclonal and polyclonal antibodies to identify Amphetamine (Amp) in urine. Amphetamine and the structurally related “designer” drugs are sympathominetic amine whose biological effects include potent central nervous system stimulation, anorectic, hypothermic, and cardiovascular properties. They are usually taken orally, intravenously, or by smoking.

 

Amphetamines are readily absorbed from the gastrointestinal tract and are then, either deactivated by the liver or excreted unchanged in the urine with a half life of about 12 hours. It can be detected in the urine for 1- 2 days after use. Amphetamine is metabolized to deaminated (hippuric and benzoic acids) and hydroxylated metabolites. Methamphetamine is partially metabolized to amphetamine and its major active metabolite.

 

Amphetamines increase the heart rate and blood pressure and suppress the appetite. Some studies indicate that heavy abuse may result in permanent damage to certain essential nerve structures in the brain.

 

Amphetamine is controlled substances. GC/MS or immunoassay method has been developed for the determination of 1000ng/ml for Amphetamine as set by the National Institute on Drug Abuse (NIDA).

 

Principle

 

The AMP Gold Rapid Screen Test Strip is a chromatographic absorbent device in which drug or drug metabolites in a sample compete with drug antigen immobilized on a porous membrane support for limited antibody sites. Labeled antibody conjugate mixes with sample specimen and binds to the free drug presented in sample forming an antibody-antigen complex. This complex prevents the formation of red color bands in the test zone immobilized antigen conjugate when the drug is presented in the sample urine above the detection levels (1000ng/ml for Amphetamine). Unbound conjugate binds to the reagent in the control zone and produces a red color band, demonstrating that the reagents and device are functioning correctly.

 

A negative specimen produces two distinct color bands, one for the control in the “C” zone and one for Amphetamine in the “T” zone.
 

Reagents and Materials Provided

 

1. Test Device

A sealed pouch contains a strip test for Amphetamine

2. Instruction for use.

 

Materials Required But Not Provided

 

1. Clock or Timer

2. A container for specimen collection

 

Warning and Precautions


1. For in vitro diagnostic use only

2. Do not use kit beyond the expiration date.

3. Urine specimens may be infectious; properly handle and dispose of all used reaction devices in biohazard container.

 

Storage

 

The kits should be stored at temperature 4-30°C the sealed pouch for the duration of the shelf life (24months).
 
Specification

 

Product Name Type Specimen Package
Amphetamine (AMP) Rapid Test strip urine 100/kit

 
Assay Procedure

 

1. Bring the urine sample and test components to room temperature if refrigerated.

 

2. When ready to test, remove the test device by tearing.

 

3. Dip the strip in the urine sample for a few seconds. Make sure that the urine level is below "Max" line. As soon as solvent front reached the membrane area place the strip on a clean surface.

 

4. Read the result in 5-10 minutes.

 

Interpretation of Results

 

Vitro Diagnostic 100 Kit 5Min AMP Drug Abuse Screening Strip 0